Xenon Xe 129 Hyperpolarized
PrescriptionHandelsnamen: XENOVIEW
About This Medication
11 DESCRIPTION XENOVIEW (xenon Xe 129 hyperpolarized) is a hyperpolarized contrast agent produced on site by the HPX Hyperpolarization System from the isotopically enriched Xenon Xe 129 Gas Blend. The Gas Blend cylinder distributed by Polarean contains xenon (1% total; > 80% isotopic purity Xe 129), nitrogen, NF (10%), and helium, NF (89%). The active pharmaceutical ingredient in XENOVIEW is hyperpolarized xenon Xe 129. Hyperpolarized xenon Xe 129 is chemically identical to non-polarized xenon Xe 129. Xenon is a clear, colorless, monoatomic, inert, stable, noble gas. It is naturally abundant in air at a level of 0.087 ppm. Atmospheric xenon is composed of nine non-radioactive isotopes, of which xenon Xe 129 comprises 26.4%. The atomic weight of xenon Xe 129 is 128.9. XENOVIEW is a clear, colorless, odorless gas for oral inhalation use. Each XENOVIEW Dose Delivery Bag contains a Dose Equivalent (DE) volume of hyperpolarized xenon Xe 129 in a volume of 250 mL to 750 mL total xenon with additional nitrogen, NF (99.999% purity) added as an inert buffer to ensure the total volume of gas reaches the dose delivery bag volume (300 mL, 500 mL, 750 mL, or 1,000 mL). The minimum DE for a dose of XENOVIEW is 75 mL with a recommended DE target range of 75 to 100 mL. DE of greater than 100 mL is acceptable.
Wirkstoffe
| Wirkstoff | Stärke |
|---|---|
| Xenon Xe-129, Hyperpolarized | - |
| Helium | - |
| Nitrogen | - |
| Xenon Xe-129 | - |
Indikationen und Anwendung
So funktioniert es
Dosierung und Verabreichung
Side Effects Overview
Warnhinweise und Vorsichtsmaßnahmen
5 WARNINGS AND PRECAUTIONS Risk of Decreased Image Quality from Supplemental Oxygen : Supplemental oxygen administered simultaneously with XENOVIEW inhalation can cause degradation of image quality. For patients on supplemental oxygen, withhold oxygen inhalation for two breaths prior to XENOVIEW inhalation, and resume oxygen inhalation immediately following the imaging breath hold. ( 5.1 ) Risk of Transient Hypoxia : Inhalation of an anoxic gas such as XENOVIEW may cause transient hypoxemia in susceptible patients. Monitor all patients for oxygen saturation and symptoms of hypoxemia, and treat as clinically indicated. ( 5.2 ) 5.1 Risk of Decreased Image Quality from Supplemental Oxygen Supplemental oxygen administered simultaneously with XENOVIEW inhalation can cause degradation of image quality due to depolarization of XENOVIEW. For patients on supplemental oxygen, withhold oxygen inhalation for two breaths prior to XENOVIEW inhalation, and resume oxygen inhalation immediately following the imaging breath hold [see Dosage and Administration ( 2.2 )] . 5.2 Risk of Transient Hypoxia Inhalation of an anoxic gas such as XENOVIEW may cause transient hypoxemia in susceptible patients [see Adverse Reactions ( 6.1 )] . Monitor all patients for oxygen desaturation and symptoms of hypoxemia, and treat as clinically indicated.
Kontraindikationen
4 CONTRAINDICATIONS None. None. ( 4 )
Pharmakokinetik
Frequently Asked Questions
1 INDICATIONS AND USAGE XENOVIEW ® , prepared from the Xenon Xe 129 Gas Blend, is indicated for use with magnetic resonance imaging (MRI) for evaluation of lung ventilation in adults and pediatric patients aged 6 years and older. Limitations of Use XENOVIEW has not been evaluated for use with lung perfusion imaging. XENOVIEW, prepared from the Xenon Xe 129 Gas Blend, is a hyperpolarized contrast agent indicated for use with magnetic resonance imaging (MRI) for evaluation of lung ventilation …
2 DOSAGE AND ADMINISTRATION The recommended target dose of XENOVIEW for adult and pediatric patients aged 6 years and older is 75 mL to 100 mL Dose Equivalent (DE) volume of hyperpolarized xenon Xe 129 by oral inhalation of the entire contents of one XENOVIEW Dose Delivery Bag. ( 2.1 ) Choose an appropriate size of the Dose Delivery Bag based on patient’s Total Lung Capacity (TLC) or Forced Vital Capacity (FVC). ( 2.1 ) Administer dose within 5 minutes …
5 WARNINGS AND PRECAUTIONS Risk of Decreased Image Quality from Supplemental Oxygen : Supplemental oxygen administered simultaneously with XENOVIEW inhalation can cause degradation of image quality. For patients on supplemental oxygen, withhold oxygen inhalation for two breaths prior to XENOVIEW inhalation, and resume oxygen inhalation immediately following the imaging breath hold. ( 5.1 ) Risk of Transient Hypoxia : Inhalation of an anoxic gas such as XENOVIEW may cause transient hypoxemia in susceptible patients. Monitor all patients for oxygen saturation …
4 CONTRAINDICATIONS None. None. ( 4 )
Xenon Xe 129 Hyperpolarized is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Inhaler Products
Browse all Inhaler products →References & Data Sources
- • DailyMed — Xenon Xe 129 Hyperpolarized drug label (National Library of Medicine)
- • openFDA — Xenon Xe 129 Hyperpolarized label data (U.S. Food & Drug Administration)
- • NDC Directory — Xenon Xe 129 Hyperpolarized (FDA National Drug Code)
Medizinischer Haftungsausschluss
Die Informationen auf dieser Seite dienen ausschließlich zu Bildungszwecken und sollten nicht als Ersatz für professionellen ärztlichen Rat, Diagnose oder Behandlung verwendet werden.
Wenden Sie sich bei Fragen zu einem medizinischen Zustand oder einem Arzneimittel stets an Ihren Arzt oder einen anderen qualifizierten Angehörigen der Gesundheitsberufe.
Datenquellen: DailyMed (NLM), openFDA, MFDS