この情報は教育目的のみに提供されています。必ず医療専門家にご相談ください。 詳しく見る

Indium In-111 Pentetate Disodium

Prescription

商品名: Indium DTPA In 111

剤形
Other
投与経路
INTRATHECAL

About This Medication

DESCRIPTION GE Healthcare (Medi-Physics, Inc.) Indium DTPA In 111 is a diagnostic drug for intrathecal use. It is available as a sterile, pyrogen-free, isotonic, aqueous solution, buffered to pH 7 to 8. At calibration time, each milliliter contains 37 MBq, 1 mCi of Pentetate Indium Disodium In 111 (no-carrier-added), 20 to 50 µ g of pentetic acid, and sodium bicarbonate for pH adjustment. The drug is to be discarded after single use. Radionuclidic purity at calibration time is at least 99.88% with less than 0.06% Indium In 114m and 0.06% Zinc Zn 65. The concentration of each radionuclidic contaminant changes with time. Graph 1 shows maximum concentration of each radionuclidic impurity as a function of time. Graph 1 - Radionuclidic Impurities The chemical names are 1. Indate(2-)- 111 In -[ N,N -bis[2-[bis-(carboxymethyl)amino]ethyl]glycinato(5-)]-disodium; and 2. Disodium [ N,N -bis[2-(carboxymethyl)amino]glycinato(5-)]-indate (2-) 111 In. Molecular formula: C 14 H 18 O 10 N 3 111 In Na 2 Molecular weight: 545.29 Structural formula: PHYSICAL CHARACTERISTICS Indium 111 decays by electron capture with a physical half-life of 67.9 hours. The energies of the photons that are useful for detection and imaging studies are listed in Table 1. Table 1. Principal Radiation Emission Data Kocher, David C.,"Radioactive Decay Data Tables,"DOE/TIC-11026, 115, (1981). Radiation Mean %/Disintegration Mean Energy (keV) Gamma-2 90.2 171.3 Gamma-3 94.0 245.4 EXTERNAL RADIATION The specific gamma ray constant for Indium In 111 is 3.3 R/hr-mCi at 1 cm. The half-value thickness of lead (Pb) for Indium In 111 is 0.021 cm. To facilitate control of the radiation exposure from millicurie amounts of this radionuclide, a range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. For example, the use of a 0.8 cm thickness of Pb will attenuate the radiation emitted by a factor of about 1,000. Table 2. Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Coefficient of Attenuation To correct for physical decay of this radionuclide, the fractions that remain at selected time intervals after the time of calibration are shown in Table 3. 0.021 0.5 0.19 10 -1 0.49 10 -2 0.80 10 -3 1.1 10 -4 Table 3. Physical Decay Chart: Indium In 111, Half-Life 67.9 Hours Hours Fraction Remaining Hours Fraction Remaining 0 Calibration Time 1.000 84 0.424 12 0.885 96 0.375 24 0.783 108 0.332 36 0.693 120 0.294 48 0.613 132 0.260 60 0.542 144 0.230 72 0.480 168 0.180 Graph 1 Structural formula

有効成分

成分 含有量
Indium In-111 Pentetate Disodium -

適応症と用法

INDICATIONS AND USAGE Pentetate Indium Disodium In 111 is recommended for use in radionuclide cisternography.

用量と投与方法

DOSAGE AND ADMINISTRATION Extreme care must be exercised to assure aseptic conditions in intrathecal injections. The maximum recommended intrathecal dose in the average patient (70 kg) is 18.5 MBq, 500 µ Ci. The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit.

Side Effects Overview

ADVERSE REACTIONS Aseptic meningitis and pyrogenic reactions have been rarely (less than 0.4%) observed following cisternography with Pentetate lndium Disodium In 111. One death has been reported to have occurred within 20 minutes following the administration of Pentetate Indium Disodium In 111 and appears to be drug related. In addition, two cases of septic meningitis have also been reported. There have also been reports of skin reactions and vomiting following administration of Pentetate lndium Disodium In 111. Relationship of the drug to these latter occurrences has not been established.

警告と注意事項

禁忌

Frequently Asked Questions

INDICATIONS AND USAGE Pentetate Indium Disodium In 111 is recommended for use in radionuclide cisternography.

DOSAGE AND ADMINISTRATION Extreme care must be exercised to assure aseptic conditions in intrathecal injections. The maximum recommended intrathecal dose in the average patient (70 kg) is 18.5 MBq, 500 µ Ci. The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit.

WARNINGS The contents of the vial are radioactive. Adequate shielding of the preparation must be maintained at all times. Since the drug is excreted by the kidneys, caution should be exercised in patients with severely impaired renal function.

CONTRAINDICATIONS None known.

Indium In-111 Pentetate Disodium is a prescription medication. You will need a valid prescription from a licensed healthcare provider.

Similar Other Products

Browse all Other products →

References & Data Sources

医療免責事項

このページの情報は教育目的のみを意図しており、専門家による医療アドバイス、診断、または治療の代替として使用すべきではありません。

疾患や医薬品に関するご質問がある場合は、必ず担当医またはその他の資格を持つ医療専門家にご相談ください。

データソース: DailyMed (NLM), openFDA, MFDS

Medical Disclaimer

This content is for educational and informational purposes only. It is not a substitute for professional medical advice, diagnosis, or treatment. Always consult a qualified healthcare provider before making medication decisions.

Data sources: ChEMBL, PubChem, DailyMed.