DESCRIPTION Xenon Xe 133 Gas is for diagnostic inhalation use only. It is supplied in vials containing either 370 or 740 megabecquerels (10 or 20 millicuries) of Xenon Xe 133 Gas in 2 milliliters of carrier xenon and atmospheric air. Xenon Xe 133 Gas is chemically and physiologically similar to elemental xenon, a non-radioactive gas which is physiologically inert except for anesthetic properties at high doses. Xenon Xe 133 is produced by fission of Uranium U 235. At the time of calibration, it contains no more than 0.3% Xenon Xe 133m, no more than 1.5% Xenon Xe 131m, no more than 0.06% Krypton Kr 85 and no more than 0.01% Iodine I 131, with no less than 99.9% total radioactivity as radioxenon. Table 1 shows the effect of time on radionuclidic composition. Table 1. Radionuclidic Composition Percent of Total Radioactivity Days % Xe-133 % Xe-133m % Xe-131m % Kr-85 % I-131 -5 >98.3 <0.6 <1.0 <0.03 <0.01 0 Calibration Date >98.1 <0.3 <1.5 <0.06 <0.01 7 >97.2 <0.08 <2.5 <0.15 <0.02 14 Expiration Date >95.7 <0.02 <4.1 <0.37 <0.02
有効成分
| 成分 | 含有量 |
|---|---|
| Xenon Xe-133 | - |
適応症と用法
用量と投与方法
Side Effects Overview
警告と注意事項
WARNINGS Xenon Xe 133 Gas delivery systems, i.e., respirators or spirometers, and associated tubing assemblies must be leakproof to avoid loss of radioactivity into the laboratory environs not specifically protected by exhaust systems. Xenon Xe 133 Gas adheres to some plastics and rubber and should not be allowed to stand in tubing or respirator containers. Loss of radioactivity due to such adherence may render the study nondiagnostic.
禁忌
CONTRAINDICATIONS None known.
Frequently Asked Questions
INDICATIONS AND USAGE Xenon Xe 133 Gas has been shown to be valuable for diagnostic inhalation studies for the evaluation of pulmonary function, for imaging the lungs and may also be applied to assessment of cerebral blood flow.
DOSAGE AND ADMINISTRATION Xenon Xe 133 Gas is administered by inhalation from a closed respirator system or spirometer. The final patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration. The recommended activity range employed for inhalation by the average patient (70 kg) is: Pulmonary function including imaging: 74 to 1110 megabecquerels (2 to 30 millicuries) Cerebral blood flow: 370 to 1110 megabecquerels (10 to 30 millicuries) This may be administered as a bolus into …
WARNINGS Xenon Xe 133 Gas delivery systems, i.e., respirators or spirometers, and associated tubing assemblies must be leakproof to avoid loss of radioactivity into the laboratory environs not specifically protected by exhaust systems. Xenon Xe 133 Gas adheres to some plastics and rubber and should not be allowed to stand in tubing or respirator containers. Loss of radioactivity due to such adherence may render the study nondiagnostic.
CONTRAINDICATIONS None known.
Xenon is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Inhaler Products
Browse all Inhaler products →References & Data Sources
- • DailyMed — Xenon drug label (National Library of Medicine)
- • openFDA — Xenon label data (U.S. Food & Drug Administration)
- • NDC Directory — Xenon (FDA National Drug Code)
医療免責事項
このページの情報は教育目的のみを意図しており、専門家による医療アドバイス、診断、または治療の代替として使用すべきではありません。
疾患や医薬品に関するご質問がある場合は、必ず担当医またはその他の資格を持つ医療専門家にご相談ください。
データソース: DailyMed (NLM), openFDA, MFDS