Technetium Tc-99M
Prescription상품명: Ultra-Technekow V4
About This Medication
DESCRIPTION The Ultra-Technekow ™ V4 Generator is prepared with fission-produced molybdenum Mo-99 adsorbed onto alumina in a column shielded by lead, tungsten, or depleted uranium. The column assembly and shielding are encased in a plastic container that is covered with a plastic elution hood. The elution hood has an opening for the column assembly double inlet needles and an opening for the single outlet needle. The needles accommodate the sterile eluant vials that contain 0.9% Sodium Chloride Injection and sterile evacuated collection vials. A sterile vial containing a bacteriostat is supplied with the generator for the customer to aseptically seal the outlet needle after each elution. This terminally sterilized generator provides a closed system for the production of sterile metastable technetium Tc-99m, which is produced by the decay of molybdenum Mo-99. Incorporated between the column outlet and the collection vial is a sterile 0.22 micrometer filter. Sterile, non-pyrogenic isotonic solutions of Sodium Pertechnetate Tc 99m Injection in 0.9% Sodium Chloride Injection can be obtained conveniently by periodic aseptic elution of the generator. These solutions should be clear, colorless, and free from any particulate matter. The Sodium Pertechnetate Tc 99m Injection is suitable for intravenous injection and direct instillation. The carrier-free solution may be used as is, or diluted to the proper concentration. Over the life of the generator, an elution will contain an amount of technetium Tc-99m in direct proportion to the quantity of Mo-99 decay since the previous elution of the generator. The quantity of Tc-99m in the eluate is determined by quantity of Mo-99 on the column, and the elapsed time between elutions. Each eluate of the generator should not contain more than the USP limit of 0.15 kilobecquerel molybdenum Mo-99 per megabecquerel technetium Tc-99m (0.15 microcurie Mo-99 per millicurie Tc-99m) per administered dose at the time of administration and an aluminum ion concentration of not more than 10 micrograms per milliliter of the generator eluate, both of which must be determined by the user before administration. Since the eluate does not contain an antimicrobial agent, it should not be used after 12 hours from the time of generator elution. Physical Characteristics Technetium Tc-99m decays by isomeric transition with a physical half-life of 6 hours. The principal photon that is useful for detection and imaging studies is listed in Table 1. Table 1. Principal Radiation Emission Data Radiation Mean Percent Per Disintegration Energy (keV) Gamma-2 89.07 140.5 External Radiation The specific gamma ray constant for technetium Tc-99m is 0.795 R/hr-mCi at 1 cm. The first half-value layer is 0.023 cm of lead (Pb). A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. For example, the use of 0.27 cm thickness of Pb will attenuate the radiation emitted by a factor of about 1000. Table 2. Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Coefficient of Attenuation 0.023 0.5 0.09 10 -1 0.18 10 -2 0.27 10 -3 Molybdenum Mo-99 decays to technetium Tc-99m with a molybdenum Mo-99 half-life of 2.75 days, or 66 hours (see Table 3). The physical decay characteristics of molybdenum Mo-99 are such that only 88.6% of the decaying molybdenum Mo-99 atoms form technetium Tc-99m. Generator elutions may be made at any time, but the amount of technetium Tc-99m available will depend on the interval measured from the last elution. Approximately 47% of the maximum available technetium Tc-99m is reached after 6 hours and 95% after 23 hours. To correct for physical decay of molybdenum Mo-99 and technetium Tc-99m, the fractions that remain at selected intervals of time are shown in Tables 3 and 4. Table 3. Physical Decay Chart; Molybdenum Mo-99, Half-Life 66 Hours Days Percent Remaining Days Percent Remaining 0 100 10 8 1 78 11 6 2 60 12 5 3 47 13 4 4 37 14 3 5 28 15 2 6 22 20 0.6 7 17 25 0.2 8 13 30 0.05 9 10 Table 4. Physical Decay Chart; Technetium Tc-99m, Half-Life 6 Hours Hours Percent Remaining Hours Percent Remaining 0* 100 9 35 1 89 10 32 2 79 11 28 3 71 12 25 4 63 14 20 5 56 16 16 6 50 18 13 7 45 24 6 8 40 *Calibration Time
유효 성분
| 성분 | 함량 |
|---|---|
| Technetium Tc-99M Sodium Pertechnetate | - |
적응증 및 용법
용량 및 투여 방법
Side Effects Overview
경고 및 주의 사항
WARNINGS Radiation risks associated with the use of Sodium Pertechnetate Tc 99m are greater in pediatric patients than in adults and, in general, the younger the patient the greater the risk owing to greater absorbed radiation doses and longer life expectancy. These greater risks should be taken firmly into account in all benefit risk assessments involving pediatric patients. Long-term cumulative radiation exposure may be associated with an increased risk of cancer. Only use generator eluant specified for use with the Ultra-Technekow ™ V4 Generator. Do not use any other generator eluant or saline from any other source.
금기
CONTRAINDICATIONS None.
Frequently Asked Questions
INDICATIONS AND USAGE The Ultra-Technekow™ V4 generator is a source of sodium pertechnetate Tc 99m for use in the preparation of FDA-approved diagnostic radiopharmaceuticals, as described in the labeling of these diagnostic radiopharmaceutical kits. Sodium Pertechnetate Tc 99m is used IN ADULTS as an agent for: Thyroid Imaging Salivary Gland Imaging Urinary Bladder Imaging (direct isotopic cystography) for detection of vesico-ureteral reflux Nasolacrimal Drainage System Imaging (dacryoscintigraphy) Sodium Pertechnetate Tc 99m is used IN PEDIATRIC PATIENTS as an agent for: …
DOSAGE AND ADMINISTRATION Sodium Pertechnetate Tc 99m is administered by intravenous injection. When imaging the nasolacrimal drainage system, instill the Sodium Pertechnetate Tc 99m by the use of a device such as a micropipette or similar method which will ensure the accuracy of the dose. For imaging the urinary bladder and ureters (direct isotopic cystography), the Sodium Pertechnetate Tc 99m is administered by direct instillation aseptically into the bladder via a urethral catheter, following which the catheter is flushed with …
WARNINGS Radiation risks associated with the use of Sodium Pertechnetate Tc 99m are greater in pediatric patients than in adults and, in general, the younger the patient the greater the risk owing to greater absorbed radiation doses and longer life expectancy. These greater risks should be taken firmly into account in all benefit risk assessments involving pediatric patients. Long-term cumulative radiation exposure may be associated with an increased risk of cancer. Only use generator eluant specified for use with the …
CONTRAINDICATIONS None.
Technetium Tc-99M is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Injection Products
Browse all Injection products →References & Data Sources
- • DailyMed — Technetium Tc-99M drug label (National Library of Medicine)
- • openFDA — Technetium Tc-99M label data (U.S. Food & Drug Administration)
- • NDC Directory — Technetium Tc-99M (FDA National Drug Code)
의료 면책 조항
이 페이지의 정보는 교육 목적으로만 제공되며, 전문적인 의학적 조언, 진단 또는 치료를 대체하는 용도로 사용해서는 안 됩니다.
의학적 상태나 의약품에 관한 질문이 있으시면 반드시 의사 또는 자격을 갖춘 의료 전문가에게 조언을 구하시기 바랍니다.
데이터 출처: DailyMed (NLM), openFDA, MFDS