Kit For The Preparation Of Technetium Tc 99M Pentetate
PrescriptionNomes comerciais: Kit for the Preparation of Technetium Tc 99m Pentetate
About This Medication
11 DESCRIPTION 11.1 Chemical Characteristics Kit for the Preparation of Technetium Tc 99m pentetate injection, a radioactive diagnostic agent, for intravenous or inhalation use. Each multiple-dose 10 mL glass vial contains a sterile, non-pyrogenic, non-radioactive lyophilized powder of 20 mg of pentetic acid, 5 mg of p-aminobenzoic acid, 3.73 mg of calcium chloride dihydrate, and not less than 0.25 mg stannous chloride dihydrate and not more than 0.385 mg maximum tin expressed as stannous chloride dihydrate. The lyophilized product is sealed under an atmosphere of nitrogen. No bacteriostatic preservative is present. Its chemical name is: Technetate (1-)99mTc,[N,N-bis[2-[bis(carboxymethyl)amino]ethyl]-glycinato(5-)]-, sodium. The structure of the technetium labeled form is: The pH is adjusted with HCl and/or NaOH prior to lyophilization so that the pH range of the reconstituted radiopharmaceutical is 6.5 to 7.5. image description 11.2 Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6 hours. The principal photon that is useful for detection and imaging studies is listed in Table 7 . Table 7 Principal Radiation Emission Data Radiation Mean % per Disintegration Mean Energy (keV) Gamma-2 88.5 140.5 The air-kerma-rate (exposure-rate) constant for Technetium Tc 99m is 5.23m 2 ·pGy·(MBq) -1 ·s -1 [0.795cm 2 ·R·(mCi) -1 ·h -1 ]. A range of values for the relative radiation attenuation by the various thicknesses of lead is shown in Table 8 . For example, the use of a 3 mm thickness of lead will attenuate the radiation emitted by a factor of about 1,000. Table 8 Radiation Attenuation by Lead Shielding Shield Thickness (Pb) mm Coefficient of Attenuation 0.25 0.5 1 10 -1 2 10 -2 3 10 -3 4 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 9 . Table 9 Physical Decay Chart of Technetium 99m Tc, Half Life: 6 Hours Hours Fraction Remaining Hours Fraction Remaining 0* 1.000 5 0.562 1 0.891 6 0.501 2 0.794 8 0.398 3 0.708 10 0.316 4 0.631 12 0.251 *Calibration Time
Princípios Ativos
| Ingrediente | Concentração |
|---|---|
| Pentetic Acid | - |
Indicações e Uso
Como funciona
Posologia e Administração
Side Effects Overview
Advertências e Precauções
5 WARNINGS AND PRECAUTIONS Hypersensitivity reactions: Hypersensitivity reactions, including anaphylaxis, have been reported during post-approval diagnostic use of Technetium Tc 99m pentetate injection. Monitor all patients for hypersensitivity reactions ( 5.1 ). Image interpretation risks in lung ventilation studies: If proximal airway deposition is observed, consider additional diagnostic options ( 5.2 ). Radiation exposure risk: Technetium Tc 99m pentetate contributes to a patient’s overall long-term radiation exposure ( 2.1 , 2.3 , 5.3 ). Bronchospasm in lung ventilation studies: Inhalation of Technetium Tc 99m pentetate solution may result in acute bronchoconstriction, especially in patients with heightened bronchoreactivity ( 5.4 ). 5.1 Hypersensitivity Reactions Hypersensitivity reactions, including anaphylaxis, have been reported during post-approval diagnostic use of Technetium Tc 99m pentetate injection. Monitor all patients for hypersensitivity reactions and have access to cardiopulmonary resuscitation equipment and personnel. 5.2 Image Interpretation Risks in Lung Ventilation Studies In patients with obstructive pulmonary disease there may be deposition of particles in the proximal airways influencing image quality and interfering with diagnostic interpretation, therefore to ensure diagnostic quality, careful use of the nebulizer to assure optimal particle delivery is essential. If interfering particle deposition occurs, consider additional diagnostic options. 5.3 Radiation Exposure Risk Technetium Tc 99m contributes to a patient’s overall long-term cumulative radiation exposure. Long-term cumulative radiation exposure is associated with an increased risk of cancer. Ensure safe handling and preparation procedures to protect patients and health care workers from unintentional radiation exposure. Use the lowest dose of Technetium Tc 99m pentetate necessary for imaging. Encourage patients to drink fluids and void as frequently as possible after intravenous administration [ see Dosage and Administration ( 2.1 , 2.3 ) ] . Radiation risks associated with the use of Technetium Tc 99m pentetate are greater in pediatric patients than in adults due to greater radiosensitivity and longer life expectancy. 5.4 Bronchospasm in Lung Ventilation Studies As with other inhaled medications, inhalation of Technetium Tc 99m pentetate solution may result in acute bronchoconstriction, especially in patients with heightened bronchoreactivity, such as patients with asthma or other lung or allergic disorders. Monitor all patients for bronchoconstriction.
Contraindicações
4 CONTRAINDICATIONS Hypersensitivity to the active ingredient or to any component of the product [ see Warnings and Precautions ( 5.1 ) ] . Hypersensitivity to the active ingredient or any component of this product ( 4 ).
Farmacocinética
Frequently Asked Questions
1 INDICATIONS AND USAGE Kit for the Preparation of Technetium Tc 99m Pentetate Injection, after radiolabeling with Technetium Tc 99m, is indicated for Kit for the Preparation of Technetium Tc 99m Pentetate Injection. Technetium Tc 99m pentetate is a radioactive diagnostic agent indicated for: Brain imaging in adults ( 1.1 ). Renal visualization, assessment of renal perfusion, and estimation of glomerular filtration rate in adult and pediatric patients ( 1.2 ). Lung ventilation imaging and evaluation of pulmonary embolism when …
2 DOSAGE AND ADMINISTRATION During preparation and handling, use water proof gloves and effective shielding, to minimize radiation exposure ( 2.1 , 5.3 ). See the Full Prescribing Information for detailed information regarding recommended Dosage and Image Acquisition Instructions ( 2.2 ) and Instructions for Drug Preparation ( 2.4 ). Do not administer more than one dose ( 2.2 ). 2.1 Radiation Safety – Drug Handling Kit for the Preparation of Technetium Tc 99m Pentetate Injection is a radioactive drug …
5 WARNINGS AND PRECAUTIONS Hypersensitivity reactions: Hypersensitivity reactions, including anaphylaxis, have been reported during post-approval diagnostic use of Technetium Tc 99m pentetate injection. Monitor all patients for hypersensitivity reactions ( 5.1 ). Image interpretation risks in lung ventilation studies: If proximal airway deposition is observed, consider additional diagnostic options ( 5.2 ). Radiation exposure risk: Technetium Tc 99m pentetate contributes to a patient’s overall long-term radiation exposure ( 2.1 , 2.3 , 5.3 ). Bronchospasm in lung ventilation studies: Inhalation …
4 CONTRAINDICATIONS Hypersensitivity to the active ingredient or to any component of the product [ see Warnings and Precautions ( 5.1 ) ] . Hypersensitivity to the active ingredient or any component of this product ( 4 ).
Kit For The Preparation Of Technetium Tc 99M Pentetate is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Injection Products
Browse all Injection products →References & Data Sources
- • DailyMed — Kit For The Preparation Of Technetium Tc 99M Pentetate drug label (National Library of Medicine)
- • openFDA — Kit For The Preparation Of Technetium Tc 99M Pentetate label data (U.S. Food & Drug Administration)
- • NDC Directory — Kit For The Preparation Of Technetium Tc 99M Pentetate (FDA National Drug Code)
Aviso Médico
As informações nesta página têm fins exclusivamente educacionais e não devem ser usadas como substituto para aconselhamento médico profissional, diagnóstico ou tratamento.
Sempre busque o aconselhamento do seu médico ou outro profissional de saúde qualificado para quaisquer dúvidas que você possa ter sobre uma condição médica ou medicamento.
Fontes de dados: DailyMed (NLM), openFDA, MFDS