Xenon Xe-133
Prescriptionชื่อทางการค้า: Xenon
About This Medication
DESCRIPTION: Xenon Xe 133 Gas is supplied in a mixture of xenon gas (5%) in carbon dioxide (95%). It is contained within septum sealed glass vials and is suitable for inhalation in the diagnostic evaluation of pulmonary function and imaging, as well as assessment of cerebral blood flow. Xenon Xe 133 Gas is reactor-produced as a by-product of Uranium U235 fission. Each vial contains the labeled amount of Xenon Xe 133 radioactivity at the time of calibration. The contents of the vial are in gaseous form, contain no preservatives, and are ready for use. Xenon Xe 133 is chemically and physiologically related to elemental Xenon, a non-radioactive monoatomic gas which is physiologically inert except for anesthetic properties at high doses. PHYSICAL CHARACTERISTICS Xenon Xe 133 decays by beta and gamma emissions with a half-life of 5.245 days. Kocher, David C., "Radioactive Decay Data Tables," DOE/TIC-11026, p. 138,1981. Significant radiations which are emitted by the nuclide are listed in Table 1. Table 1. Principal Radiation Emission Data from Xenon-133 Mean Mean % per Radiation Energy (KeV) Disintegration Beta-2 100.6 99.3 Ce-K-2 45.0 53.3 Ce-L-2 75.3 8.1 Ce-M-2 79.8 1.7 Gamma-2 81.0 36.5 K α2 X-ray 30.6 13.6 K α1 X-ray 31.0 25.3 K β X-ray 35.0 9.1 EXTERNAL RADIATION The specific gamma ray constant for Xenon Xe 133 is 3.6 microcoulombs/Kg-MBq-hr (0.51R/hr-mCi) at 1 cm. The first half value thickness of lead is 0.0035 cm. A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from the interposition of various thicknesses of Pb is shown in Table 2. For example, the use of 0.20 cm of Pb will decrease the external radiation exposure by a factor of 1,000. Table 2. Radiation Attenuation by Lead Shielding cm of Pb Radiation Attenuation Factor 0.0035 0.5 0.037 10 -1 0.12 10 -2 0.20 10 -3 0.29 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected time intervals after the time of calibration are shown in Table 3. Table 3. Xenon Xe 133 Physical Decay Chart (Half Life 5.245 days) Fraction Fraction Day Remaining Day Remaining 0 Calibration Day 1.000 8 .349 1 .877 9 .302 2 .768 10 .268 3 .674 11 .235 4 .591 12 .206 5 .518 13 .181 6 .452 14 .157 7 .398
ส่วนประกอบออกฤทธิ์
| ส่วนประกอบ | ความแรง |
|---|---|
| Xenon Xe-133 | - |
ข้อบ่งใช้และการใช้งาน
ขนาดยาและวิธีการให้ยา
Side Effects Overview
คำเตือนและข้อควรระวัง
WARNINGS: Xenon Xe 133 Gas delivery systems, i.e., respirators or spirometers, and associated tubing assemblies must be leakproof to avoid loss of radioactivity into the environs not specifically protected by exhaust systems. Xenon Xe 133 adheres to some plastics and rubber and should not be allowed to stand in tubing or respirator containers. The unrecognized loss of radioactivity from the dose for administration may render the study non-diagnostic. The vial stopper contains dry natural rubber latex and may cause allergic reactions in providers or patients who are sensitive to latex.
ข้อห้ามใช้
CONTRAINDICATIONS: None known.
Frequently Asked Questions
INDICATIONS AND USAGE: Inhalation of Xenon Xe 133 Gas has proved valuable for the evaluation of pulmonary function and for imaging the lungs. It may also be applied to assessment of cerebral flow.
DOSAGE AND ADMINISTRATION: Xenon Xe 133 Gas is administered by inhalation from closed respirator systems or spirometers. The suggested activity range employed for inhalation by the average adult patient (70 kg) is: Pulmonary function including imaging: 74-1110MBq (2-30mCi) in 3 liters of air. Cerebral blood flow: 370-1110MBq (10-30mCi) in 3 liters of air. The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration. RADIATION DOSIMETRY The estimated absorbed radiation doses Method of Calculation: A …
WARNINGS: Xenon Xe 133 Gas delivery systems, i.e., respirators or spirometers, and associated tubing assemblies must be leakproof to avoid loss of radioactivity into the environs not specifically protected by exhaust systems. Xenon Xe 133 adheres to some plastics and rubber and should not be allowed to stand in tubing or respirator containers. The unrecognized loss of radioactivity from the dose for administration may render the study non-diagnostic. The vial stopper contains dry natural rubber latex and may cause allergic …
CONTRAINDICATIONS: None known.
Xenon Xe-133 is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Inhaler Products
Browse all Inhaler products →References & Data Sources
- • DailyMed — Xenon Xe-133 drug label (National Library of Medicine)
- • openFDA — Xenon Xe-133 label data (U.S. Food & Drug Administration)
- • NDC Directory — Xenon Xe-133 (FDA National Drug Code)