Kit For The Preparation Of Technetium Tc 99M-Labeled Carbon Inhalation Aerosol
PrescriptionTên thương mại: TECHNEGAS
About This Medication
11 DESCRIPTION 11.1 Chemical Characteristics TECHNEGAS (kit for the preparation of technetium Tc 99m-labeled carbon inhalation aerosol) is a 1.25 gram black to dark grey graphite carbon crucible (Technegas Crucible). Graphite is a polymorph of the element carbon, appears opaque, and crystallizes in the hexagonal system. The crucible has the following appearance and physical dimensions: Table 3. Physical Dimensions of Crucible Length 31.25 to 32.75 mm Wall Thickness 0.39 to 0.81 mm Base Thickness 0.34 to 0.81 mm Maximum volume capacity 0.12 mL Technegas Crucible when used with sodium pertechnetate Tc 99m injection, USP in the Technegas Plus System (also commonly referred to as TechnegasPlus Technegas Generator or TP), provides technetium Tc 99m-labeled carbon inhalation aerosol in argon gas (Technegas Aerosol), a radioactive diagnostic agent for oral inhalation. During the process of formation of technetium Tc 99m-labeled carbon inhalation aerosol, when dried pertechnetate Tc 99m in Technegas Crucible is heated to 2,750°C (4,982°F) for 15 seconds in the TP using the Alternate Current arc, both the technetium and a portion of the carbon crucible are volatilized. The reduction of pertechnetate Tc 99m results in elemental technetium Tc 99m that serves as a nucleation site for the condensing of the volatile carbon, producing hydrophobic particles made up of a technetium Tc 99m core surrounded by layers of carbon. More than 90% of the technetium Tc 99m activity is technetium Tc 99m-labeled carbon particles. More than 80% of technetium Tc 99m carbon aerosol particles are < 0.92 micrometer in size. The technetium Tc 99m carbon particles are suspended in argon gas as an aerosol for inhalation. The concentration of carbon labeled particles in argon depends on the amount of technetium Tc 99m used but is less than 98 mcg/liter in Technegas Crucible loading of 0.1ml of Sodium Pertechnetate Tc99m. TECHNEGAS Crucible 11.2 Physical Characteristics Technetium-99m decays by isomeric transition with a physical half-life of 6 hours. The photon that is useful for imaging studies is listed in Table 4. Table 4. Principal Radiation Emission Data for Technetium-99m Radiation Mean % per Disintegration Mean Energy (keV) Gamma-2 88.5 140.5 The specific gamma-ray constant for technetium Tc 99m is 5.23 m2·pGy·(MBq)−1·s−1 [0.795 cm2·R·(mCi)−1·h−1]. The first half-value thickness of lead for technetium-99m is 0.017 cm (Pb). A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from the interposition of various thicknesses of lead is shown in Table 5. For example, the use of 3 mm thickness of lead will decrease the external radiation exposure by a factor of 1,000. Table 5. Radiation Attenuation by Lead Shielding Lead Shield Thickness (mm) Coefficient of Attenuation 0.25 0.5 1 0.1 2 0.01 3 0.001 4 0.0001 To correct for physical decay of this radionuclide, the fractions that remain at selected time intervals after the time of calibration are shown in Table 6. Table 6. Physical Decay Chart of Technetium-99m, Half Life: 6 Hours Hours Fraction Remaining Hours Fraction Remaining 0* 1 7 0.447 1 0.891 8 0.398 2 0.794 9 0.355 3 0.708 10 0.316 4 0.631 11 0.282 5 0.562 12 0.251 6 0.501 *Calibration Time
Chỉ định & Cách dùng
Cơ chế hoạt động
Liều dùng & Cách dùng
Side Effects Overview
Cảnh báo & Thận trọng
5 WARNINGS AND PRECAUTIONS Decreased Oxygen Saturation: Monitor oxygen saturation with continuous pulse oximetry. If clinically indicated, allow patients to breathe room air throughout the procedure and consider administration of supplemental oxygen before and at any time during the procedure. (5.1) Radiation Exposure Risk: Ensure safe handling and preparation procedures to protect patients and health care providers from unintentional radiation exposure. (2.1, 5.2) 5.1 Decreased Oxygen Saturation Decrease in oxygen saturation may occur during or after the inhalation of Technegas Aerosol. Oxygen saturation nadirs as low as 60% have been reported in a published study [see Adverse Reactions (6.1)]. In an efficacy trial, 79% of patients received supplemental oxygen or had the flow of Technegas Aerosol interrupted. Patients with compromised respiratory function may be at increased risk for decreased oxygen saturation. Monitor oxygen saturation with continuous pulse oximetry. If clinically indicated, allow patients to breathe room air throughout the procedure and consider administration of supplemental oxygen before and at any time during the procedure. 5.2 Radiation Exposure Risk Technegas Aerosol contributes to a patient’s overall long-term cumulative radiation exposure. Long-term cumulative radiation exposure is associated with an increased risk of cancer. Ensure safe handling and preparation procedures to protect patients and health care providers from unintentional radiation exposure. 5.3 Bronchospasm As with other inhaled aerosol medications, Technegas Aerosol may result in acute bronchoconstriction, especially in patients with heightened bronchoreactivity, such as patients with asthma or other lung or allergic disorders. Monitor all patients for bronchospasm.
Chống chỉ định
4 CONTRAINDICATIONS None. None (4)
Dược động học
Frequently Asked Questions
1 INDICATIONS AND USAGE TECHNEGAS, when used with sodium pertechnetate Tc 99m in the Technegas Plus System, provides technetium Tc 99m-labeled carbon inhalation aerosol (Technegas Aerosol), for use in adults and pediatric patients aged 6 years and older for: • visualization of pulmonary ventilation • evaluation of pulmonary embolism when paired with perfusion imaging TECHNEGAS, when used with sodium pertechnetate Tc 99m in the Technegas Plus System, provides technetium Tc 99m-labeled carbon inhalation aerosol (Technegas Aerosol), a radioactive diagnostic agent …
2 DOSAGE AND ADMINISTRATION For adult patients, the recommended activity of sodium pertechnetate Tc 99m injection to be loaded in the Technegas Crucible is 400 MBq to 1,000 MBq (10.8 mCi to 27 mCi) to achieve a lung count rate between 1,500 counts per second (cps) and 2,500 cps at the end of the last respiration. (2.2) For pediatric patients aged 6 years and older, a sufficient amount of Technegas Aerosol should be inhaled to achieve between 500 cps and …
5 WARNINGS AND PRECAUTIONS Decreased Oxygen Saturation: Monitor oxygen saturation with continuous pulse oximetry. If clinically indicated, allow patients to breathe room air throughout the procedure and consider administration of supplemental oxygen before and at any time during the procedure. (5.1) Radiation Exposure Risk: Ensure safe handling and preparation procedures to protect patients and health care providers from unintentional radiation exposure. (2.1, 5.2) 5.1 Decreased Oxygen Saturation Decrease in oxygen saturation may occur during or after the inhalation of Technegas …
4 CONTRAINDICATIONS None. None (4)
Kit For The Preparation Of Technetium Tc 99M-Labeled Carbon Inhalation Aerosol is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Other Products
Browse all Other products →References & Data Sources
- • DailyMed — Kit For The Preparation Of Technetium Tc 99M-Labeled Carbon Inhalation Aerosol drug label (National Library of Medicine)
- • openFDA — Kit For The Preparation Of Technetium Tc 99M-Labeled Carbon Inhalation Aerosol label data (U.S. Food & Drug Administration)
- • NDC Directory — Kit For The Preparation Of Technetium Tc 99M-Labeled Carbon Inhalation Aerosol (FDA National Drug Code)
Tuyên bố miễn trách nhiệm y tế
Thông tin trên trang này chỉ nhằm mục đích giáo dục và không nên được sử dụng thay thế cho lời khuyên y tế chuyên nghiệp, chẩn đoán hoặc điều trị.
Luôn tìm kiếm lời khuyên của bác sĩ hoặc nhà cung cấp dịch vụ y tế có chuyên môn khác đối với bất kỳ câu hỏi nào bạn có về tình trạng bệnh hoặc thuốc.
Nguồn dữ liệu: DailyMed (NLM), openFDA, MFDS