Technetium Tc-99M Exametazime
Prescription品牌名称: CERETEC
About This Medication
DESCRIPTION The Ceretec kit is supplied as a pack of 5 vials for use in the preparation of a technetium Tc99m exametazime intravenous injection as a diagnostic radiopharmaceutical for use as an adjunct in the detection of altered regional cerebral perfusion and for the radiolabeling of autologous leukocytes. Each vial of Ceretec contains a pre-dispensed sterile, non-pyrogenic, lyophilized mixture of 0.5 mg exametazime [(RR,SS)-4.8-diaza-3,6,6,9-tetramethylundecane-2, 10-dione bisoxime], 7.6 µg stannous chloride dihydrate (minimum stannous tin 0.6 µg; maximum total stannous and stannic tin 4.0 µg per vial) and 4.5 mg sodium chloride, sealed under nitrogen atmosphere with a rubber closure. The product contains no antimicrobial preservative. Prior to publication of the USAN, exametazime was formerly known as hexamethylpropylene amine oxime (HM-PAO). The name HM-PAO appears in many publications. The structural formula of exametazime is: When sterile pyrogen-free sodium pertechnetate Tc99m in isotonic saline is added to the vial of Ceretec, a Tc99m complex of exametazime is formed. Administration is by intravenous injection for diagnostic use. Physical Characteristics Technetium Tc99m decays by isomeric transition with a physical half-life of 6.03 hours. (1) Photons that are useful for imaging studies are listed in Table 1. Table 1. Principal Radiation Emission Data-technetium Tc99m Radiation Mean %/ Disintegration Mean Energy (keV) (1) Dillman, L.T. and Von der Lage, F.C. Radionuclide decay schemes and nuclear parameters for use in radiation-dose estimation. MIRD Phamphlet No. 10, p. 62, 1975. Gamma 2 87.87 140.5 External Radiation The specific gamma ray constant for technetium Tc99m is 206 microCoulomb kg-1/37 MBq-h, (0.8 R/millicurie-h) at 1 cm. The first half-value thickness of lead (Pb) for technetium Tc99m is 0.2 mm. A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. For example, the use of a 2.7 mm thickness of Pb will decrease the external radiation exposure by a factor of 1,000. Table 2. Radiation Attenuation by Lead Shielding Shield Thickness (Pb) mm Coefficient of Attenuation 0.2 0.5 0.95 10 –1 1.8 10 –2 2.7 10 –3 3.6 10 –4 4.5 10 –5 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals relative to the time of calibration are shown in Table 3. Table 3. Physical Decay Chart: Tc99m half-life 6.03 hours Hours Fraction Remaining Hours Fraction Remaining 0 Calibration time (time of preparation) 1.000 7 0.447 1 0.891 8 0.399 2 0.795 9 0.355 3 0.708 10 0.317 4 0.631 11 0.282 5 0.563 12 0.252 6 0.502 24 0.063 Chemical Structure
活性成分
| 成分 | 规格 |
|---|---|
| Technetium Tc-99M Exametazime | - |
适应证与用法
用法用量
Side Effects Overview
禁忌证
CONTRAINDICATIONS None known.
Frequently Asked Questions
INDICATIONS AND USAGE Technetium Tc99m exametazime scintigraphy may be useful as an adjunct in the detection of altered regional cerebral perfusion in stroke. Tc99m exametazime is indicated for leukocyte labeled scintigraphy as an adjunct in the localization of intra-abdominal infection and inflammatory bowel disease.
DOSAGE AND ADMINISTRATION Tc99m labeled leukocytes for adjunctive localization of intra-abdominal infection or inflammation. The normal adult (70 kg) dose is 0.259-0.925 GBq (7-25 mCi) as Tc99m labeled leukocytes by intravenous injection. Optimal planar imaging is between 2-4 hours. Cerebral Scintigraphy The recommended dose range for i.v. administration, of reconstituted sodium pertechnetate Tc99m exametazime in the average adult (70 kg) is 370-740 MBq (10-20 mCi). Dynamic imaging may be performed between 0 to 10 minutes following injection. Static imaging may …
CONTRAINDICATIONS None known.
Technetium Tc-99M Exametazime is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Injection Products
Browse all Injection products →References & Data Sources
- • DailyMed — Technetium Tc-99M Exametazime drug label (National Library of Medicine)
- • openFDA — Technetium Tc-99M Exametazime label data (U.S. Food & Drug Administration)
- • NDC Directory — Technetium Tc-99M Exametazime (FDA National Drug Code)
医疗免责声明