هذه المعلومات للأغراض التعليمية فقط. استشر دائمًا متخصصًا صحيًا. اعرف أكثر

Noxivent 102

Prescription

الأسماء التجارية: Noxivent 102

الشكل الصيدلاني
Inhaler
طريق الإعطاء
RESPIRATORY (INHALATION)
الشركة المصنِّعة
Linde Gas & Equipment Inc

About This Medication

11. DESCRIPTION Noxivent™ (nitric oxide gas) is a drug administered by inhalation. Nitric oxide, the active substance in Noxivent™, is a pulmonary vasodilator. Noxivent™ is a gaseous blend of nitric oxide and nitrogen (0.08% and 99.92%, respectively for 800 ppm; 0.01% and 99.99%, respectively for 100 ppm). Noxivent™ is supplied in aluminum cylinders as a compressed gas under high pressure (2000 pounds per square inch gauge [psig]). The structural formula of nitric oxide (NO) is shown below: formula

المواد الفعالة

المادة الفعالة التركيز
Nitric Oxide -

المؤشرات العلاجية والاستخدام

INDICATIONS AND USAGE Noxivent™ is a vasodilator indicated to improve oxygenation and reduce the need for extracorporeal membrane oxygenation in term and near-term (>34 weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension in conjunction with ventilatory support and other appropriate agents.

الجرعة وطريقة الإعطاء

DOSAGE AND ADMINISTRATION The recommended dose is 20 ppm, maintained for up to 14 days or until the underlying oxygen desaturation has resolved ( 2.1 ). Doses greater than 20 ppm are not recommended ( 2.1 , 5.2 ) Administration: • Avoid abrupt discontinuation ( 2.2 , 5.1 ).

Side Effects Overview

ADVERSE REACTIONS The most common adverse reaction is hypotension. ( 6 ). To report SUSPECTED ADVERSE REACTIONS, contact Linde, Inc. at 1-800-772-9247 and www.linde.com or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch .

التحذيرات والاحتياطات

موانع الاستعمال

Frequently Asked Questions

INDICATIONS AND USAGE Noxivent™ is a vasodilator indicated to improve oxygenation and reduce the need for extracorporeal membrane oxygenation in term and near-term (>34 weeks gestation) neonates with hypoxic respiratory failure associated with clinical or echocardiographic evidence of pulmonary hypertension in conjunction with ventilatory support and other appropriate agents.

DOSAGE AND ADMINISTRATION The recommended dose is 20 ppm, maintained for up to 14 days or until the underlying oxygen desaturation has resolved ( 2.1 ). Doses greater than 20 ppm are not recommended ( 2.1 , 5.2 ) Administration: • Avoid abrupt discontinuation ( 2.2 , 5.1 ).

WARNINGS AND PRECAUTIONS Rebound: Abrupt discontinuation of Noxivent™ may lead to worsening oxygenation and increasing pulmonary artery pressure ( 5.1 ). Methemoglobinemia: Methemoglobin increases with the dose of nitric oxide; following discontinuation or reduction of nitric oxide, methemoglobin levels return to baseline over a period of hours ( 5.2 ). Elevated NO 2 Levels: Monitor NO 2 levels ( 5.3 ). Heart Failure: In patients with pre-existing left ventricular dysfunction, Noxivent™ may increase pulmonary capillary wedge pressure leading to pulmonary …

CONTRAINDICATIONS Neonates dependent on right-to-left shunting of blood ( 4 ).

Noxivent 102 is a prescription medication. You will need a valid prescription from a licensed healthcare provider.

Similar Inhaler Products

Browse all Inhaler products →

References & Data Sources

إخلاء المسؤولية الطبية

المعلومات الواردة في هذه الصفحة مخصصة للأغراض التعليمية فقط ولا ينبغي استخدامها بديلًا عن المشورة الطبية المتخصصة أو التشخيص أو العلاج.

استشر دائمًا طبيبك أو أي مقدم رعاية صحية مؤهل بشأن أي أسئلة تتعلق بحالة طبية أو دواء.

مصادر البيانات: DailyMed (NLM), openFDA, MFDS

Medical Disclaimer

This content is for educational and informational purposes only. It is not a substitute for professional medical advice, diagnosis, or treatment. Always consult a qualified healthcare provider before making medication decisions.

Data sources: ChEMBL, PubChem, DailyMed.