Revakinagene Taroretcel-Lwey
PrescriptionNoms de marque : ENCELTO
About This Medication
11 DESCRIPTION ENCELTO (revakinagene taroretcel-lwey) implant, is single-dose, sterile, nonpyrogenic and retrievable. ENCELTO is an allogeneic encapsulated cell-based gene therapy that contains 200,000 to 440,000 allogeneic retinal pigment epithelial cells expressing recombinant human ciliary neurotrophic factor (rhCNTF) (NTC-201-6A cell line) for surgical intravitreal placement. ENCELTO consists of an opaque, semi-permeable white to off-white capsule surrounding a scaffold of polyethylene terephthalate (PET) yarn, loaded with rhCNTF secreting allogeneic retinal pigment epithelial cells (NTC-201-6A cell line). Each end of the semi-permeable capsule is sealed with medical grade methacrylate adhesive, and to one end a titanium fixation loop is attached. ENCELTO width is 1.2 ± 0.1 mm, length is 6.1 ± 0.4 mm, and its internal diameter is 0.88 ± 0.02 mm ( Figure 17 ). ENCELTO is packaged in a protective inner container within an orange to pink liquid hold medium referred to as Endothelial Serum Free Media (Endo-SFM), which is maintained sterile by a sealed outer container. ENCELTO is provided attached, by the fixation loop, to a gripper that both suspends ENCELTO in the Endo-SFM and facilitates intraocular insertion. The Endo-SFM within the packaging inner container may contain visible particles generally described as fiber, solid, white, or metallic in appearance. ENCELTO is manufactured using animal and human derived reagents.
Principes Actifs
| Ingrédient | Dosage |
|---|---|
| Revakinagene Taroretcel | - |
Indications et Utilisation
Posologie et Administration
Side Effects Overview
Mises en Garde et Précautions
5 WARNINGS AND PRECAUTIONS ENCELTO implantation has been associated with severe vision loss, infectious endophthalmitis, retinal tears and/or detachment, vitreous hemorrhage, implant extrusion, cataract formation, suture related complications, and delayed dark adaptation. Patients should be instructed to report signs or symptoms that could be associated with these events without delay. Additional surgical and/or medical management may be required. ( 5.1 , 5.2 , 5.3 , 5.4 , 5.5 , 5.6 , 5.7 , 5.8 ) Vitreous Hemorrhage: Temporarily discontinue antithrombotic medication prior to ENCELTO insertion surgery to reduce the risk of implantation related vitreous hemorrhage. Vitreous hemorrhages occurring greater than one year from implantation could be a sign of ENCELTO extrusion. The surgical site should be examined closely and the ENCELTO should be surgically repositioned if indicated. ( 5.4 ) 5.1 Severe Vision Loss Severe vision loss defined as three or more lines of visual acuity loss [≥15 Early Treatment Diabetic Retinopathy Study (ETDRS) letters] has occurred following ENCELTO implantation [ see Adverse Reactions (6) ]. Monitor patients for signs and symptoms of vision loss and manage as clinically indicated. 5.2 Infectious Endophthalmitis Infectious endophthalmitis may occur following ENCELTO implantation. Signs and symptoms of infectious endophthalmitis include progressively worsening eye pain, vision loss, or scleral and conjunctival injection. To mitigate the risk of endophthalmitis, use proper aseptic surgical technique for ENCELTO implantation [ see Dosage and Administration (2.2) ]. Monitor patients for signs or symptoms of infectious endophthalmitis. Remove ENCELTO implant if infectious endophthalmitis occurs and manage symptoms according to clinical practice. 5.3 Retinal Tear and Detachment Retinal tears and retinal detachment may occur following ENCELTO implantation. Signs and symptoms of retinal tears include acute onset of flashing lights, floaters, and/or loss of visual acuity. Signs and symptoms of retinal detachment may include progressive visual field loss and/or loss of visual acuity. Use standard vitreoretinal surgical techniques during ENCELTO implantation to minimize the risk of retinal tears and retinal detachment. Monitor for any signs or symptoms of retinal tear and/or retinal detachment. Treat rhegmatogenous retinal detachment and retinal tears promptly. Remove ENCELTO implant, if vitrectomy with a complete gas fill or silicone oil fill is required [ see Dosage and Administration (2.3) ]. 5.4 Vitreous Hemorrhage Vitreous hemorrhage, which may result in temporary vision loss, has occurred following ENCELTO implantation [ see Adverse Reactions (6) ]. Patients receiving antithrombotic medication (e.g., oral anticoagulants, aspirin, nonsteroidal anti-inflammatory drugs) may be at increased risk of vitreous hemorrhage. To reduce the risk of vitreous hemorrhage, interrupt antithrombotic medications prior to the ENCELTO implantation. Vitrectomy surgery may be necessary to clear severe, recurrent, or non-clearing vitreous hemorrhage. If the patient has a late onset vitreous hemorrhage (greater than one year following ENCELTO implantation surgery), examine the ENCELTO implantation site for possible implant extrusion. If implant extrusion has occurred, surgically reposition ENCELTO [ see Implant Extrusion (5.5) ]. 5.5 Implant Extrusion Implant extrusion through the initial scleral wound has occurred following ENCELTO implantation [ see Adverse Reactions (6) ]. Signs and symptoms of implant extrusion include recurrent uveitis, vitreous hemorrhage, eye pain more than one year after implantation, or visibility of titanium fixation loop under the conjunctiva. To reduce the risk of implant extrusion, carefully follow the specific surgical steps for ENCELTO implantation [ see Dosage and Administration (2.2) ]. Evaluate patients after 6 months to confirm proper positioning of ENCELTO and then annually. If ENCELTO begins to extrude, surgically reposition ENCELTO to a proper scleral wound depth either in the same site or in the opposing inferior quadrant of the vitreous cavity. 5.6 Cataract Formation Cataract formation, including cataract cortical, cataract nuclear, cataract subcapsular, cataract traumatic, and lenticular opacities, has occurred following ENCELTO implantation [ see Adverse Reactions (6) ]. To reduce the risk of ENCELTO-related cataract formation or progression, carefully follow the specific surgical steps for ENCELTO implantation [ see Dosage and Administration (2.2) ]. 5.7 Suture Related Complications Suture related complications, including conjunctival erosions due to suture tips and suture knots, have occurred following ENCELTO implantation [ see Adverse Reactions (6) ]. To mitigate the risk of suture related complications, carefully follow the specific surgical steps for ENCELTO implantation [ see Dosage and Administration (2.2) ] and manage suture-related complications as clinically indicated. 5.8 Delayed Dark Adaptation Delayed Dark Adaptation, a delay in the ability to adjust vision from a bright lighting condition to a dim lighting, has occurred following ENCELTO administration which remained unchanged for the duration of study follow up [ see Adverse Reactions (6) ]. Advise patients to take caution while driving and navigating in the dark.
Contre-indications
4 CONTRAINDICATIONS ENCELTO is contraindicated in patients with: Active or suspected ocular or periocular infections. Known hypersensitivity to Endothelial Serum Free Media (Endo-SFM) Ocular or periocular infections. ( 4 ) Known hypersensitivity to Endothelial Serum Free Media (Endo-SFM). ( 4 )
Frequently Asked Questions
1 INDICATIONS AND USAGE ENCELTO is indicated for the treatment of adults with idiopathic macular telangiectasia type 2 (MacTel). ENCELTO is an allogeneic encapsulated cell-based gene therapy indicated for the treatment of adults with idiopathic macular telangiectasia type 2 (MacTel).
2 DOSAGE AND ADMINISTRATION For intravitreal implantation only. ENCELTO is intended for surgical intravitreal implantation under aseptic conditions by a qualified ophthalmologist. ( 2.1 ) The recommended dose is one ENCELTO implant per affected eye containing 200,000 to 440,000 allogeneic retinal pigment epithelial cells expressing recombinant human ciliary neurotrophic factor (rhCNTF). ( 2.1 ) Carefully inspect ENCELTO prior to use and refer to the Instructions for Use when preparing for and performing surgical placement or removal of ENCELTO. ( 2.2 …
5 WARNINGS AND PRECAUTIONS ENCELTO implantation has been associated with severe vision loss, infectious endophthalmitis, retinal tears and/or detachment, vitreous hemorrhage, implant extrusion, cataract formation, suture related complications, and delayed dark adaptation. Patients should be instructed to report signs or symptoms that could be associated with these events without delay. Additional surgical and/or medical management may be required. ( 5.1 , 5.2 , 5.3 , 5.4 , 5.5 , 5.6 , 5.7 , 5.8 ) Vitreous Hemorrhage: Temporarily discontinue antithrombotic …
4 CONTRAINDICATIONS ENCELTO is contraindicated in patients with: Active or suspected ocular or periocular infections. Known hypersensitivity to Endothelial Serum Free Media (Endo-SFM) Ocular or periocular infections. ( 4 ) Known hypersensitivity to Endothelial Serum Free Media (Endo-SFM). ( 4 )
Revakinagene Taroretcel-Lwey is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Other Products
Browse all Other products →References & Data Sources
- • DailyMed — Revakinagene Taroretcel-Lwey drug label (National Library of Medicine)
- • openFDA — Revakinagene Taroretcel-Lwey label data (U.S. Food & Drug Administration)
- • RxNorm — RXCUI 2708837 (NLM Normalized Drug Names)
- • NDC Directory — Revakinagene Taroretcel-Lwey (FDA National Drug Code)
Avertissement Médical
Les informations sur cette page sont destinées à des fins éducatives uniquement et ne doivent pas être utilisées en remplacement d'un avis médical professionnel, d'un diagnostic ou d'un traitement.
Consultez toujours votre médecin ou tout autre professionnel de santé qualifié pour toute question relative à une condition médicale ou à un médicament.
Sources des données : DailyMed (NLM), openFDA, MFDS