Estas informações têm fins exclusivamente educacionais. Sempre consulte um profissional de saúde. Saiba mais

Technetium Tc99M Pyrophosphate

Prescription

Nomes comerciais: Kit for the Preparation of Technetium Tc99m Pyrophosphate

Forma Farmacêutica
Injection
Via de Administração
INTRAVENOUS

About This Medication

DESCRIPTION Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection is a multidose reaction vial which contains the sterile, non-pyrogenic, non-radioactive ingredients necessary to produce Technetium Tc 99m Pyrophosphate Injection for diagnostic use by intravenous injection. Each 10 mL vial contains 12.0 mg of sodium pyrophosphate, 2.8 mg minimum stannous tin as stannous chloride dihydrate and 4.9 mg maximum total tin as stannous chloride dihydrate; pH is adjusted to 5.3-5.7 with hydrochloric acid prior to lyophilization. No bacteriostatic preservative is present. Sealed under nitrogen. The chemical names are: (1) Diphosphoric acid, Ditin (2 + ) salt; (2) Ditin (2 + ) pyrophosphate (4 - ). The structural formula is: When a solution of sterile, non-pyrogenic, oxidant-free isotonic Sodium Pertechnetate Tc 99m Injection U.S.P. is added to the vial, Technetium Tc 99m Pyrophosphate Injection is formed for intravenous injection. When a solution of sterile, non-pyrogenic, isotonic saline is added to the vial, it forms a blood pool imaging agent when Sodium Pertechnetate Tc 99m Injection is injected intravenously 30 minutes after the intravenous administration of the non-radioactive reconstituted Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection. The precise structure of Technetium Tc 99m Pyrophosphate Injection is not known at this time. Structural Formula Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6.02 hours.¹ The principal photon that is useful for detection and imaging studies is listed in Table 1. TABLE 1: Principal Radiation Emission Data Radiation Mean Percent Per Disintegration Mean Energy (keV) Gamma-2 89.07 140.5 ¹Kocher DC: Radioactive decay data tables. DOE/TIC-11026: 108, 1981 External Radiation The specific gamma ray constant for Tc 99m is 0.78 R/hr-millicurie at 1 cm. The first half-value layer is 0.017 cm of lead (Pb). A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. For example, the use of a 0.25 cm thickness of Pb will attenuate the radiation emitted by a factor of about 1,000. TABLE 2: Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Coefficient of Attenuation 0.017 0.5 0.08 10 -1 0.16 10 -2 0.25 10 -3 0.33 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 3. TABLE 3: Physical Decay Chart: Tc 99m, half-life 6.02 hours Hours Fraction Remaining Hours Fraction Remaining 0* 1.000 7 0.447 1 0.891 8 0.398 2 0.794 9 0.355 3 0.708 10 0.316 4 0.631 11 0.282 5 0.562 12 0.251 6 0.501 * Calibration time

Princípios Ativos

Ingrediente Concentração
Technetium Tc-99M Pyrophosphate -

Indicações e Uso

INDICATIONS AND USAGE Technetium Tc 99m Pyrophosphate Injection is a bone imaging agent used to demonstrate areas of altered osteogenesis, and a cardiac imaging agent used as an adjunct in the diagnosis of acute myocardial infarction. Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection is a blood pool imaging agent which may be used for gated blood pool imaging and for the detection of sites of gastrointestinal bleeding. When reconstituted with sterile non-pyrogenic isotonic saline and administered intravenously 30 minutes prior to the intravenous administration of Sodium Pertechnetate Tc 99m Injection, approximately 76% of the injected radioactivity remains in the blood pool.

Posologia e Administração

DOSAGE AND ADMINISTRATION After preparation with oxidant-free Sodium Pertechnetate Tc 99m Injection, the suggested dose range of Technetium Tc 99m Pyrophosphate Injection in the average ADULT patient (70 kg) is: Bone Imaging - 185-555 megabecquerels (5-15 mCi) Cardiac Imaging - 370-555 megabecquerels (10-15 mCi) The suggested dose range of the non-radioactive reconstituted Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection in the average ADULT patient (70 kg) is: Blood Imaging - Administer not less than one-third nor more than the total contents of one vial [555 - 740 megabecquerels (15-20mCi) of Pertechnetate Tc 99m Injection]. Bone and Cardiac Imaging Technetium Tc 99m Pyrophosphate Injection is injected intravenously over a 10 to 20 second period. For optimal results, bone imaging should be done 1 to 6 hours following administration. Cardiac imaging should be done 30 to 90 minutes following administration. The acute myocardial infarct can be visualized from 24 hours to 6 days following onset of symptoms, with maximum localization at 48 to 72 hours. Cardiac imaging should be done with a gamma scintillation camera. It is recommended that images be made of the anterior, left anterior oblique and left lateral projections. Blood Pool Imaging Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection may be reconstituted with sterile, non-pyrogenic isotonic saline containing no preservatives. Administer not less than one-third nor more than the total contents of one vial 30 minutes prior to the intravenous administration of 555 to 740 megabecquerels (15-20 mCi) Sodium Pertechnetate Tc 99m Injection. The non-radioactive reconstituted Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection should be injected by direct venipuncture. Heparinized catheter systems should be avoided. Cardiac imaging should be done 10 to 30 minutes following the administration of Sodium Pertechnetate Tc 99m Injection utilizing a scintillation camera interfaced to an electrocardiographic gating device. Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit. The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration. Radiation Dosimetry Bone and Cardiac Imaging The effective half-life was assumed to be the physical half-life for all calculated values. The estimated radiation absorbed doses to an average ADULT patient (70 kg) from an intravenous injection of a maximum of 555 megabecquerels (15 mCi) of Technetium Tc 99m Pyrophosphate Injection are shown in Table 4. TABLE 4: Estimated Absorbed Radiation Doses Bone and Cardiac Imaging* Technetium Tc 99m Pyrophosphate Injection Target Organ mGy/555 MBq rads/15 mCi Total Body 1.8 0.18 Kidneys 3.6 0.36 Red Marrow 3.5 0.35 Bone Surfaces 21.1 2.11 Bladder Wall 13.3 1.33 Testes 1.4 0.14 Ovaries 2.1 0.21 Effective Dose Equivalent 3.3 mSv 0.33 rem *Based on the model in MIRD Dose Estimate Report No. 13 (J Nucl Med 30:1117-1122, 1989). Estimate calculated using phantoms of Cristy & Eckerman (Report ORNL/TM-8381/V1 & V7). Bone and marrow model of Eckerman (Aspects of dosimetry of radionuclides within the skeleton with particular emphasis on the active marrow. In Fourth International Radiopharmaceutical Dosimetry Symposium; A.T. Schlafke-Stelson and E.E. Watson eds. CONF-851113, Oak Ridge Associated Universities, Oak Ridge, TN 37831, 1986. pp 514-534.) used. The effective dose equivalent is a quantity which may be suitable for comparing risks of different procedures in nuclear medicine, radiology, and other applications involving ionizing radiation, but should not be construed to give information about risks to individual patients and should not be applied to situations involving radiation therapy. Blood Pool Imaging The estimated absorbed radiation doses to an average adult patient (70 kg) from an intravenous injection of 740 megabecquerels (20 mCi) of Sodium Pertechnetate Tc 99m Injection, 30 minutes after the intravenous administration of the non-radioactive reconstituted Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection are shown in Table 5. TABLE 5: Estimated Absorbed Radiation Doses Blood Pool Imaging a Sodium Pertechnetate Tc 99m 30 min. Post Injection with Pyrophosphate Target Organ mGy/740 MBq rads/20 mCi Total Body 3.2 0.32 Spleen 3.6 0.36 Bladder Wall b 24.0 2.40 Testes 2.4 0.24 Ovaries 4.6 0.46 Blood 10.4 1.04 Red Marrow 4.4 0.44 a Assume 75% of the Sodium Pertechnetate Tc 99m labels red blood cells and the other 25% remains as pertechnetate. Method of calculation: MIRD Dose Estimate Report No. 8, J Nucl Med . 17: 74-77, 1976. b If 25% excreted with 1 hour T b

Side Effects Overview

ADVERSE REACTIONS Some hypersensitivity reactions have been associated with pyrophosphate use.

Advertências e Precauções

Contraindicações

Frequently Asked Questions

INDICATIONS AND USAGE Technetium Tc 99m Pyrophosphate Injection is a bone imaging agent used to demonstrate areas of altered osteogenesis, and a cardiac imaging agent used as an adjunct in the diagnosis of acute myocardial infarction. Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection is a blood pool imaging agent which may be used for gated blood pool imaging and for the detection of sites of gastrointestinal bleeding. When reconstituted with sterile non-pyrogenic isotonic saline and administered intravenously …

DOSAGE AND ADMINISTRATION After preparation with oxidant-free Sodium Pertechnetate Tc 99m Injection, the suggested dose range of Technetium Tc 99m Pyrophosphate Injection in the average ADULT patient (70 kg) is: Bone Imaging - 185-555 megabecquerels (5-15 mCi) Cardiac Imaging - 370-555 megabecquerels (10-15 mCi) The suggested dose range of the non-radioactive reconstituted Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection in the average ADULT patient (70 kg) is: Blood Imaging - Administer not less than one-third nor more …

WARNINGS As an adjunct in the diagnosis of confirmed myocardial infarction (ECG and serum enzymes positive), the incidence of false negative images has been found to be 6 percent. False negative images can also occur if made prior to 24 hours in the evolutionary phase of the infarct or after 6 days in the resolution phase. In a limited study involving 22 patients in whom the ECG was positive and serum enzymes questionable or negative, but in whom the final …

CONTRAINDICATIONS None known.

Technetium Tc99M Pyrophosphate is a prescription medication. You will need a valid prescription from a licensed healthcare provider.

Similar Injection Products

Browse all Injection products →

References & Data Sources

Aviso Médico

As informações nesta página têm fins exclusivamente educacionais e não devem ser usadas como substituto para aconselhamento médico profissional, diagnóstico ou tratamento.

Sempre busque o aconselhamento do seu médico ou outro profissional de saúde qualificado para quaisquer dúvidas que você possa ter sobre uma condição médica ou medicamento.

Fontes de dados: DailyMed (NLM), openFDA, MFDS

Medical Disclaimer

This content is for educational and informational purposes only. It is not a substitute for professional medical advice, diagnosis, or treatment. Always consult a qualified healthcare provider before making medication decisions.

Data sources: ChEMBL, PubChem, DailyMed.