Technetium Tc99M Pyrophosphate
PrescriptionТорговые наименования: Kit for the Preparation of Technetium Tc99m Pyrophosphate
About This Medication
DESCRIPTION Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection is a multidose reaction vial which contains the sterile, non-pyrogenic, non-radioactive ingredients necessary to produce Technetium Tc 99m Pyrophosphate Injection for diagnostic use by intravenous injection. Each 10 mL vial contains 12.0 mg of sodium pyrophosphate, 2.8 mg minimum stannous tin as stannous chloride dihydrate and 4.9 mg maximum total tin as stannous chloride dihydrate; pH is adjusted to 5.3-5.7 with hydrochloric acid prior to lyophilization. No bacteriostatic preservative is present. Sealed under nitrogen. The chemical names are: (1) Diphosphoric acid, Ditin (2 + ) salt; (2) Ditin (2 + ) pyrophosphate (4 - ). The structural formula is: When a solution of sterile, non-pyrogenic, oxidant-free isotonic Sodium Pertechnetate Tc 99m Injection U.S.P. is added to the vial, Technetium Tc 99m Pyrophosphate Injection is formed for intravenous injection. When a solution of sterile, non-pyrogenic, isotonic saline is added to the vial, it forms a blood pool imaging agent when Sodium Pertechnetate Tc 99m Injection is injected intravenously 30 minutes after the intravenous administration of the non-radioactive reconstituted Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection. The precise structure of Technetium Tc 99m Pyrophosphate Injection is not known at this time. Structural Formula Physical Characteristics Technetium Tc 99m decays by isomeric transition with a physical half-life of 6.02 hours.¹ The principal photon that is useful for detection and imaging studies is listed in Table 1. TABLE 1: Principal Radiation Emission Data Radiation Mean Percent Per Disintegration Mean Energy (keV) Gamma-2 89.07 140.5 ¹Kocher DC: Radioactive decay data tables. DOE/TIC-11026: 108, 1981 External Radiation The specific gamma ray constant for Tc 99m is 0.78 R/hr-millicurie at 1 cm. The first half-value layer is 0.017 cm of lead (Pb). A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. For example, the use of a 0.25 cm thickness of Pb will attenuate the radiation emitted by a factor of about 1,000. TABLE 2: Radiation Attenuation by Lead Shielding Shield Thickness (Pb) cm Coefficient of Attenuation 0.017 0.5 0.08 10 -1 0.16 10 -2 0.25 10 -3 0.33 10 -4 To correct for physical decay of this radionuclide, the fractions that remain at selected intervals after the time of calibration are shown in Table 3. TABLE 3: Physical Decay Chart: Tc 99m, half-life 6.02 hours Hours Fraction Remaining Hours Fraction Remaining 0* 1.000 7 0.447 1 0.891 8 0.398 2 0.794 9 0.355 3 0.708 10 0.316 4 0.631 11 0.282 5 0.562 12 0.251 6 0.501 * Calibration time
Действующие Вещества
| Компонент | Дозировка |
|---|---|
| Technetium Tc-99M Pyrophosphate | - |
Показания и Применение
Дозировка и Способ Применения
Side Effects Overview
Предупреждения и Меры Предосторожности
WARNINGS As an adjunct in the diagnosis of confirmed myocardial infarction (ECG and serum enzymes positive), the incidence of false negative images has been found to be 6 percent. False negative images can also occur if made prior to 24 hours in the evolutionary phase of the infarct or after 6 days in the resolution phase. In a limited study involving 22 patients in whom the ECG was positive and serum enzymes questionable or negative, but in whom the final diagnosis of acute myocardial infarction was made, the incidence of false negative images was 23 percent. The incidence of false positive images has been found to be 7 to 9 percent. False positive images have also been reported following coronary by-pass graft surgery, in unstable angina pectoris, old myocardial infarcts and in cardiac contusions. Preliminary reports indicate impairment of brain scans using Sodium Pertechnetate Tc99m Injection which have been preceded by a bone scan using an agent containing stannous ions. The impairment may result in false positive or false negative brain scans. It is recommended, where feasible, that brain scans precede bone imaging procedures. Alternately, a brain imaging agent such as Technetium Tc 99m Pentetate Injection may be employed. The biodistribution of technetium Tc 99m pyrophosphate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. High levels of these cations may be caused by concomitant medications or medical conditions (e.g., iron overload, hypercalcemia, etc.). Most cases were observed after iron infusion. (See PRECAUTIONS, Drug Interactions .)
Противопоказания
CONTRAINDICATIONS None known.
Frequently Asked Questions
INDICATIONS AND USAGE Technetium Tc 99m Pyrophosphate Injection is a bone imaging agent used to demonstrate areas of altered osteogenesis, and a cardiac imaging agent used as an adjunct in the diagnosis of acute myocardial infarction. Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection is a blood pool imaging agent which may be used for gated blood pool imaging and for the detection of sites of gastrointestinal bleeding. When reconstituted with sterile non-pyrogenic isotonic saline and administered intravenously …
DOSAGE AND ADMINISTRATION After preparation with oxidant-free Sodium Pertechnetate Tc 99m Injection, the suggested dose range of Technetium Tc 99m Pyrophosphate Injection in the average ADULT patient (70 kg) is: Bone Imaging - 185-555 megabecquerels (5-15 mCi) Cardiac Imaging - 370-555 megabecquerels (10-15 mCi) The suggested dose range of the non-radioactive reconstituted Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection in the average ADULT patient (70 kg) is: Blood Imaging - Administer not less than one-third nor more …
WARNINGS As an adjunct in the diagnosis of confirmed myocardial infarction (ECG and serum enzymes positive), the incidence of false negative images has been found to be 6 percent. False negative images can also occur if made prior to 24 hours in the evolutionary phase of the infarct or after 6 days in the resolution phase. In a limited study involving 22 patients in whom the ECG was positive and serum enzymes questionable or negative, but in whom the final …
CONTRAINDICATIONS None known.
Technetium Tc99M Pyrophosphate is a prescription medication. You will need a valid prescription from a licensed healthcare provider.
Similar Injection Products
Browse all Injection products →References & Data Sources
- • DailyMed — Technetium Tc99M Pyrophosphate drug label (National Library of Medicine)
- • openFDA — Technetium Tc99M Pyrophosphate label data (U.S. Food & Drug Administration)
- • NDC Directory — Technetium Tc99M Pyrophosphate (FDA National Drug Code)
Медицинский Отказ от Ответственности
Информация на данной странице предназначена исключительно в образовательных целях и не должна использоваться в качестве замены профессиональной медицинской консультации, диагностики или лечения.
Всегда обращайтесь за советом к своему врачу или иному квалифицированному медицинскому работнику по любым вопросам, связанным с состоянием здоровья или лекарственными препаратами.
Источники данных: DailyMed (NLM), openFDA, MFDS